The Trisobuild® HW system is a horizontally run external wall system that allows the secondary steelwork to remain horizontal with the spacer system spanning vertically between these rails.

Bracket height (mm) Insulation depth (mm) U-value (W/m2K)
120 140 0.35
140 140 0.30
160 160 0.26
180 180 0.23
200 200 0.21

Above U-values based on a LP1000 liner, secondary steelwork support at 1.5m centres, 1.5m bracket spacing and insulation with a 0.040W/mK thermal conductivity.